色美女视频 I 国产无人区卡一卡二卡三乱码99 I 打屁股sp惩罚调教91 I 亚洲欧美va天堂人熟伦 I 国产成人专区 I 日韩国产人妻一区二区三区 I 日韩精品综合在线 I 亚洲国产视频一区二区 I 操比网 I 日韩www在线观看 I wwww亚洲熟妇久久久久 I 亚洲日韩一区精品射精 I 国内精品久久久久影院蜜芽 I 伊人国 I 自拍亚洲国产 I 在线观看91精品国产网站 I 国产日韩精品欧美一区喷水 I 99偷拍视频精品一区二区 I av综合网站 I 香蕉久久夜色 I 久草在线资源网站 I 黄色精品一区二区 I 一本一本久久a久久综合精品蜜桃 I 伊人久久天堂 I 97日日碰人人模人人澡 I 1313午夜精品美女爱做视频 I 男人的天堂色 I 日本成人免费视频 I 成人手机视频在线 I 国产精品对白刺激在线观看 I 天堂av一区二区 I 91九色蝌蚪popny I 玉足软肉夹住摩擦出白浆视频 I 男人和女人在一起污污的app I 又色又爽又黄视频网站

How does the electro-hydraulic directional valve work?

  • 7062 Views
  • 2018-12-20

The electro-hydraulic directional valve is composed of a two normally open solenoid valve, a two normally closed solenoid valve, and two 3/8 "ball valves (needle valves). The normally open solenoid valve is installed on the upstream pipeline of the controlled circuit, and the normally closed solenoid valve is installed on the downstream pipeline of the controlled circuit.

In the process of transporting medium through pipelines, when a valve needs to be opened, the computer sends a valve opening signal, and the normally open solenoid valve is energized (closed), while the normally closed solenoid valve is energized (opened). At this point, the channel from the upstream to the chamber on the main valve diaphragm is cut off, and the channel from the chamber on the main valve diaphragm to the downstream is opened. At this point, the pressure at the lower part of the diaphragm is higher than the pressure at the upper part. The medium in the chamber on the main valve diaphragm is discharged to the downstream pipeline through the normally closed solenoid valve channel, and the main valve is opened.

When the valve needs to be closed, the computer sends a valve closing signal, and the normally open solenoid valve is disconnected (opened), while the normally closed solenoid valve is disconnected (closed). At this point, the channel from upstream to the chamber on the main valve diaphragm is opened, and the channel from the chamber on the main valve diaphragm to downstream is closed. The high-pressure medium upstream enters the chamber on the main valve diaphragm through a normally open solenoid valve. At this point, the upper and lower pressures of the diaphragm are equal, causing the main valve to close under the action of spring force.

During the opening and closing process of the main valve, the normally open solenoid valve is energized (closed) and the normally closed solenoid valve is de-energized (closed). At this point, both the upstream and downstream channels are in a cut-off state, and the medium pressure is trapped in the upper chamber of the main valve diaphragm, causing the main valve to be locked in a fixed open position due to hydraulic pressure difference, thereby maintaining a constant flow rate from the main valve outlet. When the upstream flow changes, the computer sends a signal to the corresponding solenoid valve based on the feedback signal of the flow meter, which can automatically adjust to the pre-set flow value again.