色美女视频 I 国产无人区卡一卡二卡三乱码99 I 打屁股sp惩罚调教91 I 亚洲欧美va天堂人熟伦 I 国产成人专区 I 日韩国产人妻一区二区三区 I 日韩精品综合在线 I 亚洲国产视频一区二区 I 操比网 I 日韩www在线观看 I wwww亚洲熟妇久久久久 I 亚洲日韩一区精品射精 I 国内精品久久久久影院蜜芽 I 伊人国 I 自拍亚洲国产 I 在线观看91精品国产网站 I 国产日韩精品欧美一区喷水 I 99偷拍视频精品一区二区 I av综合网站 I 香蕉久久夜色 I 久草在线资源网站 I 黄色精品一区二区 I 一本一本久久a久久综合精品蜜桃 I 伊人久久天堂 I 97日日碰人人模人人澡 I 1313午夜精品美女爱做视频 I 男人的天堂色 I 日本成人免费视频 I 成人手机视频在线 I 国产精品对白刺激在线观看 I 天堂av一区二区 I 91九色蝌蚪popny I 玉足软肉夹住摩擦出白浆视频 I 男人和女人在一起污污的app I 又色又爽又黄视频网站

Analysis of Types and Selection of Control Valves in the Power Industry

  • 5072 Views
  • 2017-03-07
Simply put, the power flow diagram is actually a cycle process of water and steam, and selecting control valves in this process is both simple and complex. The simple thing is that the process medium is simple, with only two types: water and steam. The complex thing is that the temperature and pressure fluctuations of water and steam are large, causing a series of problems such as flash evaporation, cavitation, erosion, noise, and corrosion. But the first thing to consider is the safety and reliability of the control valve.

We will follow the system process to provide instructions for selecting control valves.

1. Main and auxiliary boiler feed water valves and composite feed water regulating valves:

Control requirements: Control the boiler inlet water, maintain the boiler liquid level and steam flow.

Working condition requirements: When the boiler is started, the valve pressure difference can reach 100-300 kilograms, and the flow rate is small. During normal operation, the pressure difference is small, and the flow rate is large. The adjustable ratio of flow rate is 75:1 to 100:1.

Valve requirements: The valve body material is WCB/WC9. For start-up valves in dual valve systems, resistance to cavitation is required, with a V-class closure rating. For composite feed water valves, characteristic valve trims are required to meet the needs of boiler start-up and normal operation. Generally, the valve is selected as fault closed. (It should be noted that in order to eliminate dissolved oxygen in the water supply, hydrazine is added for treatment, which can cause adverse reactions to SATELLITE 6 alloy or other similar alloys. Therefore, 316STELLITE surfacing welding method is not used to treat the valve internals, and 416 stainless steel material can be directly used.).

2. Boiler feed pump minimum flow circulation valve:

Control requirements: Ensure the safe start and operation of the boiler feedwater pump, and eliminate pump damage caused by low flow rate, increased temperature rise, and strong water cavitation. (Old power plants used switch type minimum flow control valves, as well as mechanical pump automatic circulation valves.).

Working condition: The pressure drop reaches 160-350 kilograms, and it is the valve that bears the largest pressure difference in the power plant system. The flow rate is generally 30% of the normal flow rate.

Valve requirements: anti cavitation, anti clogging structure, V-class sealing grade, continuous operation of the valve during pump start and stop operation, and closing of the valve after normal pump start. The valve is usually open due to malfunction.

3. High/low heater feed water heater drainage, condensate heater drainage:

Control requirements: Control the position of condensate water in the heater, and timely discharge the condensate water, i.e. discharge at high water level and drain at normal water level.

Working condition: the medium is saturated water, the pressure difference of control valves between heaters is generally 6-30kg, and the last stage drain valve is directly connected to the condenser or deaerator.

Valve requirements: Anti flash erosion, Class V or VI sealing rating, and the valve is usually open due to malfunction.

4. Deaerator water level control valve (DALC):

Control requirements: Provide flow to maintain the normal water level of the deaerator, and increase the water temperature by adding steam to eliminate dissolved gases in the water.

Working condition: During the startup phase, the flow rate is small and the pressure difference is large. Under normal circumstances, the flow rate is large and the pressure difference is small, and the working condition is similar to that of a water supply valve.

Valve requirements: Effective resistance to cavitation at low flow rates.

5. Desuperheating valve (desuperheater):

Control requirements: Inject high-pressure water into the steam to ensure that the steam temperature meets the control requirements.

Working condition: The medium is water, with a large pressure difference. Valve requirements: diverse types: nozzle type, auxiliary atomization type, self contained type, and wafer type.

6. Temperature and pressure reducing valves (high and low pressure bypass valves):

Control requirements: Adjust the high-temperature and high-pressure steam to a certain temperature and pressure of steam; Provide a bypass channel for the steam turbine, and the boiler can operate independently of the steam turbine.
Working condition: High temperature and high pressure steam temperature and pressure reduction.

Valve requirements: thermal shock resistance, noise reduction, rapid response.